The impeller is the heart of a slurry pump. Its type decides how well the pump passes solids, how it wears and how efficiently it runs.
Three impeller types
- Open impeller — vanes with no shrouds. Best solids passage and least clogging, but lower efficiency and more wear on the vanes. Suited to fibrous and stringy slurry.
- Semi-open impeller — one shroud, one open side. A balance of solids handling, efficiency and wear. The common choice for general slurry.
- Closed impeller — vanes enclosed by two shrouds. Highest efficiency, but narrow passages clog more easily and solids handling is limited. Used for cleaner slurry.
How slurry type drives the choice
- Fibrous, stringy, semi-solid slurry → open or semi-open, non-clog design (NSEW family).
- Abrasive, hard-particle slurry → semi-open with wear-resistant material (SSEW family).
- High-head slurry → impeller geometry engineered for pressure as well as solids (SSSEW family).
Vanes and solids passage
Fewer, wider vanes pass larger solids but reduce efficiency. More vanes improve efficiency but clog more easily. Slurry impellers usually use fewer vanes with wider passages than clean-water impellers.
Why selection needs review
Impeller choice interacts with material, flow and head. The wrong impeller clogs, wears fast or runs inefficiently. HET confirms the impeller type and size against your slurry and duty point during engineering review.