Head is the energy a pump adds to the liquid, expressed as a height of liquid column. For slurry, head calculation must account for the density of the mixture, not just water.
Components of total head
Total dynamic head is the sum of:
- Static head — the vertical distance between the slurry surface and the discharge point.
- Friction head — losses in the suction and discharge pipeline from flow resistance.
- Pressure head — any pressure required at the delivery point.
- Velocity head — usually small, often negligible.
The slurry density correction
Pump performance curves are typically based on water. When pumping a denser slurry, the pressure the pump must produce rises in proportion to the mixture specific gravity. A slurry with a specific gravity of 1.3 requires roughly 1.3 times the pressure of water for the same head in metres of mixture.
Why high-head slurry is harder
High-head slurry duty combines dense liquid with high discharge pressure. This loads the impeller, increases wear and demands a pump engineered for pressure as well as abrasion — which is the purpose of the HET SSSEW high-head slurry family.
When to request engineering review
Head calculation for slurry is sensitive to pipeline size, length, fittings and slurry density. Small errors compound into large pump selection mistakes. For any non-trivial installation, confirm the calculation with HET engineering before selection.